<LOGO>
FM Transmitter Measurement Report
Created: 2025-07-25 08-20-26
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
107.90 MHz 5/5, 76 dBuV Call Me
Pilot RDS Phase Difference
6.9 kHz 2.0 kHz 56 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
8 kHz 10 kHz 12485 0,0000
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
-4,6 dBr -1,93 dBr 0,6 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"Call Me " 43B2 7 (Culture) 0 1 1 1 7:20, 25.07.2025
RT
"Orchester "
AF EON
88.5, 91.7, 93.0, 93.2, 93.7, 94.0, 94.9, 95.4, 96.6, 97.3, 97.7, 99.0, 99.1, 99.4, 99.5, 99.6, 100.7, 102.5, 103.2, 104.1, 104.9 MHz 43B1, 43B3
FM Scope Max at: 10 kHz MIN: 8 kHz % above 76 kHz: 0,0000 Acquired: 2025/07/25 8.19.22 Total samples: 12485 Equivalent time: 0:10:24 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 200 400 600
FM Scope MAX: 0,6 dBr MIN: -4,6 dBr AVE: -1,93 dBr % above 12,2 dBr: 0,0 Last value: -2,6 dBr (2025/07/25 8.19.22) 08.06 08.08 08.10 08.12 08.14 08.16 08.18 -4 -2 0 Pm [dBr]